PRODUCT LEAFLET TRANSFORMERS TYPE TED Network Transformers (0.4 to 160 kVA)
Aprire il catalogo a pagina 1
PRODUCTS PRESENTATION SINGLE PHASE TRANSFORMERS FOR SINGLE PHASE NETWORKS Concentric two-pole cable NETWORK ACCESSORIES Two-pole boxes : Dead end box 1 A Junction 1 A / 1 D Derivation 1 A / 2 D Derivation 1 A / 3 D SINGLE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS Single pole or three pole cables Network accessories three pole box 1 A / 1 D THREE PHASE TRANSFORMERS FOR THREE PHASE NETWORKS Single-pole or three-pole cables
Aprire il catalogo a pagina 2
NETWORK TRANSFORMERS Type TED 0.4 to 160 kVA « Lead through » connection
Aprire il catalogo a pagina 3
ALL THE AVANTAGES OF EPOXY RESINS For single-phase (400 VA to 50 kVA) or three-phase (5 kVA to 32 kVA) unpluggable transformers The use of epoxy resin guarantees that the transformers have the following characteristics: Corrosion resistant, remain unaltered over time. Watertight and immersible. Insulated. Can be buried into purposely-designed pits. MODULOBLOCS: MAIN CHARACTERISTICS Watertight and immersible sets. Conform to NFC 52 410 standards. Dielectric : Oil Primary insulation voltage : 7.2 kV Secondary insulation voltage : 1.1 kV Reduced losses Protection degree : IP 68 - IK 10 Working...
Aprire il catalogo a pagina 4
DOUBLE «AUTO» PROTECTED TRANSFORMERS: The protection devices directly incorporated in the transformer guarantee : MV protection by easily accessible HRC fuses. Optional: Low Voltage protection by means of thero-magnetic circuit breakers allows protection against short circuiting, linked to thermal protection with of a probe incorperated in the windings which guarantees elimination of possible permanent faults. Protection by HRC fuses. Four-pole circuit breaker on a TED TTT 10 kVA TED TRANSFORMERS: ADVANTAGES Complete range of equipment, to enable absence of voltage tests (VAT) to be carried...
Aprire il catalogo a pagina 5
TED MMX - 0.4 to 10 kVA TYPE Single-phase transformer for single-phase networks. Cast in resin, corrosion resistant, water-tight, plug-in connection designed for directly buried installation. Protection degree : IP 68 Primary voltage : 3200 V (1) Primary winding insulation level : 7,2 kV Secondary no-load voltage : 237 V (2) Secondary winding insulation level : 1,1 kV Coupling : single-phase Dielectric : oil Power rating : 400, 630, 1000, 2000, 3000, 5000, 10000 VA Nominal power depending on public lighting standards 320, 504, 800, 1600, 2400, 4000, 8000 VA Transformers comply with NFC 52...
Aprire il catalogo a pagina 6
MV fuses MV Input terminal Output terminal Rating plate Earth terminal LV protection (optional) Two-pole LV output TED MMX TECHNICAL DATA - 0.4 to 10 kVA Power rating (kVA) Short-circuit impedance (%) Magnetising current (%)
Aprire il catalogo a pagina 7
TED MMX - 16, 25, 32, 50 kVA TYPE Single-phase transformer for single-phase networks. Cast in resin, corrosion resistant, water-tight, plug-in connection designed for directly buried installation. Protection degree : IP 68 Primary voltage : 3200 V (1) Primary winding insulation level : 7.2 kV Secondary no-load voltage : 237 V (2) Secondary winding insulation level : 1.1 kV Coupling : single phase Dielectric : oil Power rating : 16 - 25 - 32 - 50 kVA Nominal power depending on public lighting standards 12.8 - 20 - 25.6 - 40 kVA Transformers comply with NFC 52 410 standards. OPERATING...
Aprire il catalogo a pagina 8
LV Protection (optional) LV Output MV adjustment switch Two-pole unpluggable terminals MV fuses TED MMX TECHNICAL DATA - 16, 25, 32, 50 kVA Power rating (kVA) Short-circuit impedance (%) Magnetising current (%)
Aprire il catalogo a pagina 9
ACCESSORIES FOR SINGLE-PHASE NETWORKS JUNCTION AND DEVIATION BOXES WITH EARTHING OF THE PERIPHERAL CABLE DEAD END BOX, JUNCTION AND DEVIATION BOXES These different boxes made up of pluggable universal two-pole consentric terminals receive either a concentric two-pole 3.6 / 6 kV cable, or a radical field single pole 3.6 / 6 kV cable made up of a twisted cable strut. A single pole cable’s cross section can be either 6, 10, 16, 25 or 35 mm². External diameter of the watertight outer covering can’t exceed 24 mm. On all these boxes it is possible to add an earthing terminal connected to the...
Aprire il catalogo a pagina 10
LINE DEAD END SPARKS GAP Network in TNRS* diagram with a concentric two-pole cable The peripheral conductors (neutral) of the concentric two pole 3.5/6 kV cable are insulated to 1000 V level. In the event of using this cable with a TNRS distribution system, accidental damage to cable will result in a short circuit with the central conductor (3.5/6 kV); causing peripheral voltage to exceed the 1000 V limit to 3200 V. This can also be caused by the primary winding of the TED transformer. A line dead end spark gap results in a connection between the peripheral cable and the earth. An...
Aprire il catalogo a pagina 11
TWO-POLE TERMINAL MODEL X GENERAL INFORMATION This terminal consists of two parts : a- the plug is joined to the device and contains a central and periphical contact. It is designed to receive all plugs from 6 to 25mm². b- the plug is on the cable. The parts ensuring electric contacts must be adapted to cable cross-section. PROTECTION AGAINST WATER PENETRATION This is carried out in two stages : Between the sheath (3) and the envelope with the help of an o-ring seal (4). Toughness: 70° shore, +/- 5°. Between the cable and the sheath (3) with the help of a thermo-retractable sheath. NB:...
Aprire il catalogo a pagina 12
Accessories for the two-pole plug 1- Screwing nut 2- Thermo-retractable sleeve 3- Sheath 4- O-ring seal 5- Peripheral nozzle 6- Under the peripheral nozzle 7- Central nozzle 8- Spacer 9- Nut Mounted two-pole plug Plugged-in and then waterproofed two-pole plug
Aprire il catalogo a pagina 13
TED MTT - 2, 3, 5, 10 kVA TYPE Single-phase transformer for three -phase networks. Cast in resin, corrosion resistant, water-tight, plug-in connection designed for directly buried installation. Protection degree : IP 68 Primary voltage : 5500 V (1) Primary winding insulation level : 7.2 kV Secondary no-load voltage : 237 V (2) Secondary winding insulation level : 1.1 kV Coupling : single-phase Dielectric : oil Power rating : 2 - 3 - 5 - 10 kVA Nominal power depending on public lighting standards : 1.6 - 2.4 - 4 - 8 kVA Transformers comply with NFC 52410 standards. OPERATING CONDITIONS...
Aprire il catalogo a pagina 14Tutti i cataloghi e le schede tecniche Augier
-
TER TRANSFORMER
24 Pagine
-
DIAM 4100
8 Pagine
-
CLA - Compact Lighting Arrester
4 Pagine
-
Switch Over
8 Pagine
-
Marklight work area marking
8 Pagine
-
Marklight
8 Pagine
-
CDE 12/13 cells
8 Pagine
-
Sub-stations
24 Pagine
-
DIAM 3100
8 Pagine
-
DIAM 4000
4 Pagine
-
MHV dimmer
4 Pagine
-
TSE transformer
4 Pagine
-
COMPACTO
12 Pagine
-
OPTIMOFLUX
8 Pagine
-
COMPACTO TT IP68
8 Pagine
-
TTAET Transformer for tunnels
4 Pagine
-
Dry transformer
8 Pagine
-
Power transformer
4 Pagine
-
Modulobloc
20 Pagine
-
Augier-Box
4 Pagine