Estratti del catalogo
Load Cells Celle di Carico
Aprire il catalogo a pagina 1RE-SOLVING MACHINING LAMINATES REQUIRES AUTOMATED PROCESSES, AND AUTOMATION REQUIRES A RANGE OF EQUIPMENT DESIGNED TO OPTIMISE PRODUCTION AND REDUCE TIMES, COSTS AND THE RISK OF ERROR. IF YOU WANT TO FIND ALL THIS IN ONE BRAND NAME ONLY, ASK AND ASK AGAIN. THE ANSWER WILL ALWAYS BE: RE. LA LAVORAZIONE DEI LAMINATI RICHIEDE PROCESSI AUTOMATIZZATI. L’AUTOMAZIONE RICHIEDE EQUIPAGGIAMENTI DIVERSI, TUTTI MIRATI A OTTIMIZZARE LA PRODUZIONE, RIDUCENDO TEMPI, COSTI E RISCHI DI ERRORE. SE VUOI TROVARE TUTTO IN UN NOME SOLO, CHIEDI E RICHIEDI. IN MOLTI TI DIRANNO: RE.
Aprire il catalogo a pagina 2Precisely measuring and keeping constant the tension of a moving web is essential in order to obtain constant product quality and to maximize productivity. Re load cells, in a precise tension control system, are designed to carry out these delicate tasks and determine their success in terms of both quality and price, meeting our customers’ needs and expectations. Re load cells have been designed and produced in Italy for over 40 years, they can be used to measure tension in various sectors: paper, cardboard, plastic film, sheet metal, rubber, fabric, metal wire and can be installed in any...
Aprire il catalogo a pagina 3CF SERIES SERIE CF Features • • • • Flange mounting Easy installation Load range: 50÷25.000 N Overload protection Montaggio a flangia Semplicità di installazione Range di carico: 50÷25.000 N Protezione al sovraccarico CH SERIES SERIE CH Features • • • • • Flange mounting Double metal foil: high precision level Exceptional mounting flexibility Load range: 250÷1.000 N Overload protection Montaggio a flangia Realizzazione a doppia lamina: elevata precisione Estrema flessibilità di fissaggio Range di carico: 250÷1.000 N Protezione al sovraccarico CK SERIES SERIE CK Features • • • • • Flange...
Aprire il catalogo a pagina 4CB SERIES SERIE CB Features • • • • • Base mounting Mounting with foot bearing support Load range: 150÷30.000 N High resistance Overload protection Montaggio a basamento Montaggio con supporto portacuscinetto a piede Range di carico: 150÷30.000 N Elevata resistenza alle vibrazioni Protezione al sovraccarico SENSOR ROLLER CPF SERIES RULLO SENSORE SERIE CPF Features • • • • • • Sensor roller with cantilever mounting Roll length 250 to 600 mm Double metal foil: high precision level Load range: 50÷700 N Optional integrated amplifier with display Overload protection Rullo sensore con montaggio a...
Aprire il catalogo a pagina 5SYMBOLS AND UNIT OF MEASUREMENT Ftension Proller SIMBOLI E UNITÀ DI MISURA • Resultant direction Direzione risultante Reading direction Direzione lettura Winding angles [degrees] Angolo di avvolgimento [gradi] α/2 Tension (T) Risultante sulla cella [N] α/2 Forza della tensione [N] Force per load cell [N] ForzaRoller per cella di carico [N] Tensione totale del laminato [N] PesoFdel rullo [N] tension Ftension Proller GUIDE FOR LOAD CELL SELECTION GUIDA ALLA SCELTA DELLA CELLA DI CARICO wrap angle α Proller Proller To select the load cell suited to your wrap angle needs, α you must find out...
Aprire il catalogo a pagina 6GUIDE FOR LOAD CELL SELECTION GUIDA ALLA SCELTA DELLA CELLA DI CARICO Horizontal resultant Horizontal resultant is the best configuration for load cells, since it does not detect the weight of the roller. That configuration is recommended for low web tension. The result obtained refers to a single load cell. Downward resultant In the configuration with downward resultant the weight of the roller (P) supplies a positive signal which will be considered the tare. For a zero-set electrically subtract the roller weight value. Upward resultant In the configuration with upward resultant the weight...
Aprire il catalogo a pagina 7CF SERIES LOAD CELLS FLANGE MOUNTED / CELLE DI CARICO A FLANGIA Load cell with self-aligning locating bearing Cella con cuscinetto orientabile fisso The flanged load cells, CF series, fitted at the end of a measuring roller, can precisely detect the resultant of the forces generated by pulling of the material depending on the winding angles. The commercial success of these cells is due to the combination of several elements: a compact design, which allows them to be easily fitted in narrow spaces, their user-friendliness and a high reliability; the latter is due to the high quality...
Aprire il catalogo a pagina 8Code Codice Code Codice Ball bearing Cuscinetto Code Codice Ball bearing Cuscinetto
Aprire il catalogo a pagina 9Code Codice Code Codice Ball bearing Cuscinetto Code Codice
Aprire il catalogo a pagina 10CH SERIES LOAD CELLS FLANGE MOUNTING / CELLE DI CARICO A FLANGIA Roller holder kit Kit portarullo CH load cell Flange Flangia Clamp for roller fixing Kit guscio CH Chamaleon load cells are usually installed at the end of a cantilever measuring roller or pulley to precisely detect the resultant of the forces generated by pulling of the material depending on the wrapping angle. Le celle di carico Camaleonte CH sono solitamente installate all’estremità di un rullo di misura a sbalzo, o su una puleggia, e sono in grado di rilevare con precisione la risultante delle forze generate dal tiro del...
Aprire il catalogo a pagina 11CH + FLANGE + ROLLER HOLDER KIT CH + FLANGIA + KIT PORTARULLO Code Codice Code Codice CH + FLANGE + CLAMP FOR ROLLER FIXING CH + FLANGIA + KIT GUSCIO OPTIONAL Green parts OPTIONAL Parti verdi Back side: fixing flange Front side: kit roll holder fixing clamp for roller fixing axial press gland (standard) lateral press gland pressacavo assiale (standard) pressacavo laterale
Aprire il catalogo a pagina 12A-3 SERIES LOAD CELLS FLANGE MOUNTING / CELLE DI CARICO A FLANGIA 60 M8 connector Connettore M8 Red point resultant direction Punto rosso direzione risultante Ball bearing Thanks to its compact design and easy fixing, A-3 load cell is quickly installed at the end of a measuring roller even in very narrow spaces. The load cell detect, with very high accuracy, the force resulatnt generated by the web tension depending on the wrapping angle and send the signal to a Re load cell amplifier to process the values. A-3 load cells are available in various models and with a load range from 50 N to...
Aprire il catalogo a pagina 13Tutti i cataloghi e le schede tecniche Re S.p.A.
-
REGOLATORI DI TENSIONE
20 Pagine
-
REDRIVE SPINGI BOBINA
8 Pagine
-
SISTEMI GUIDANASTRO
24 Pagine
-
FRENI PNEUMATICI A PINZA
28 Pagine
-
SISTEMA DI VISIONE REVISION
8 Pagine
-
ALBERI E SUPPORTI
16 Pagine
-
GIUNTI ROTANTI
8 Pagine
-
Mechanical chucks
12 Pagine