CLM-36
6Pagine

{{requestButtons}}

Estratti del catalogo

CLM-36 - 1

MISURATORI CAPACITIVI IN CONTINUO Capacitive level meters CLM – 36 Capacitive level meters Riels CLM® are designed for continuous level measurement of liquids, powders and bulk-solid materials in vessels, tanks, sumps, containers, silos, etc. CLM consists of the stainless steel housing with electronic module and the measuring electrode. Type of measuring electrode is defined by kind of use and type of measured media. Sensitivity (SPAN) and initial capacity compensation (ZERO) can be fluently set. CLMs are offered in version (N) for non-hazardous environments or (Xi) version to explosive areas up to zone 0 or zone 20, high temperature performance and several types of process coupling are also available. Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments • For continuous level measurement of liquid and bulk-solid materials • Direct mounting into containers, silos, vessels, basins, reservoirs, etc • Easy and quick connecting by connector • Continuous adjustment of initial capacity • Variants for usage in explosive areas, high temperature performance • Current (4 ... 20 mA) or voltage (0 ... 10 V) output With uncoated rod electrode for level measurement of non-conductive liquids (oils, diesel, petrol) and powder or bulk-solid materials (flour, sand, cement, plastic granulates, etc.). Max. length 5 m. With fully (FEP) coated rod electrode for level measurement of water and conductive liquids incl. wasted liquids in metallic vessels, concrete sumps, reservoirs, etc., better behaviour against aggressive media, lower adhesion to some complicated media, chemical resistance. Max. length 3 m. With uncoated rod electrode and reference tube for accurate level measurement of clean nonconductive liquids (oils, diesel, petrol). By means of reference tube the output signal does not depend on the dimensions and shapes of a vessel. Max. length 3 m. With fully FEP coated rod electrode and reference tube for accurate level measurement of conductive liquids. Main use is for measurement in plastic vessels or tanks. Impossible to use for waste and high viscosity liquids and bulk-solid materials. Max. length 3 m. With uncoated stainless steel rope electrode and uncoated weight for level measurement of bulk-solid materials (grains, sand, flour, cement, etc.). Max. length 20 m. With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. Max. length 20 m. With fully coated rope electrode and coated weight (rope insulation FEP, weight insulation PTFE), for level measurement of electrically conductive and non-conductive liquids. Max. length 20 m. With two coated electrodes (rode insulation FEP, head fully PTFE), for level measurement of aggressive liquids. Performance for non-explosive areas only. Max. length 2 m. Accessories Standard – included in the level meter price Optional (see datasheets "Accessories") • 1x of seal, other seals are on request (PTFE, Al, etc.) • 1x connector socket • 1x screwdriver for adjustment (each 5 pcs) • Distance element for rods longer than 50 cm (for CLM – 36_–40) • Connector with protection class IP67 (GAN–DADE 7A) with 5 m cable (current output) • Connector with protection class IP67 (GAN–DAAE 7A) with 5 m cable (voltage output) • Steel welding fl ange ON–36x2 • Stainless steel welding flange NN–36x2 • Stainless steel fixing nut UM–36x2 • Dust-tight bushing PR–31 • Anchor welding cylinder KV–31 Safety, protections, compatibility and explosion proof Level meter CLM–36 is equipped with protection against electric shock on electrode, reverse polarity, output current overload, short circuit and short time over voltages. Electromagnetic compatibility is provided by conformity with standards: EN 55022/B, EN 61326-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6. Explosion proof of CLM–36Xi is examined by FTZÚ-AO 210 Ostrava - Radvanice certificate No.: FTZÚ 02 ATEX 0235

Aprire il catalogo a pagina 1
CLM-36 - 2

Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Dimensions drawings

Aprire il catalogo a pagina 2
CLM-36 - 3

Technical specifications (variants N, NT) 9 ... 36 V DC 16 ... 36 V DC 4 ... 20 mA 0 ... 10 V approx. 8 mA 20 ; 30 ; 50 ; 100 ; 150 ; 300 ; 500 ; 1000 pF min. 1:2 max. 1 % max. 0.05% / K max. 0.3 μA/V and 0.1 mV/V 1 MΩ / 250 V AC 51 nF / 250 V AC IP67 (Housing), IP65 (Connector) IP67 Rmax= 750 Ω Rmin > 1 kΩ approx. 0.5 kg approx. 1 kg CLM – 36N(T)–_ _–_–I Supply voltage CLM – 36N(T)–_ _–_–U Current output Voltage output Power consumption (off-load) CLM–36N(T)–_ _–_–U Sensitivity ranges Initial capacity regulation ratio Nolinearity Temperature error Voltage error for current and voltage...

Aprire il catalogo a pagina 3
CLM-36 - 4

Temperature and pressure durability (variants N, Xi) Variants / Performance Max. operation pressure for temperature tp to 30°C to 85°C Temperature and pressure durability (variants NT, XiT) Temperature tp CLM –36_T–10, 20 CLM –36_T–12, 22 CLM –36_T–30 CLM –36_T–31 (incl. PR–31) CLM –36_T–31 (incl. KV–31) CLM –36_T–32 Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Variants / Performance Max. operation pressure for temperature tp to 30°C to 85°C to 130°C to 160°C to 200°C 7 MPa 6 MPa 7 MPa – – 1 MPa Influence of the tank shape to linearity of...

Aprire il catalogo a pagina 4
CLM-36 - 5

Installation Level meters are designed to mounting in vertical position on the top lid of a tank or a container by means of welding flanges, stainless steel fixing nuts or Triclamp coupling. When installed into metallic wall vessel it is not necessary to ground the housing of CLM. In the case of use in concrete basins or silos it is recommended to install the CLM on metallic bracket or auxiliary metallic construction electrically connected with the liquid (water), or connected with metallic armour of silo. In the case of measuring in glass or plastic vessels by CLM without the reference...

Aprire il catalogo a pagina 5

Tutti i cataloghi e le schede tecniche Riels Instruments

  1. CLF

    2 Pagine

  2. FT1-FT1A

    2 Pagine

  3. D100

    2 Pagine

  4. CLT

    1 Pagine

  5. TS-TSA

    2 Pagine

  6. N2015

    1 Pagine

  7. EE31

    6 Pagine

  8. TQX

    2 Pagine

  9. F3.05

    3 Pagine

  10. PFMV

    6 Pagine

  11. PFMB

    21 Pagine

  12. MS-RI-X

    3 Pagine

  13. RIF600P

    3 Pagine

  14. PF3W

    16 Pagine

  15. FHKSC

    3 Pagine

  16. EPI

    2 Pagine

  17. VZS-005-VA

    1 Pagine

  18. LFE

    22 Pagine

  19. K-PULSER

    2 Pagine

  20. K-EL

    2 Pagine

  21. K-33/44

    2 Pagine

  22. K33 ATEX

    2 Pagine

  23. VZO 4/8

    4 Pagine

  24. VZF

    7 Pagine

  25. VZO 15...50

    7 Pagine

  26. F RANGE

    4 Pagine

  27. KDN

    3 Pagine

  28. KPO

    3 Pagine

  29. ZHM-KL

    5 Pagine

  30. ZHM-ST

    5 Pagine

  31. WI-N

    2 Pagine

  32. AFM/ACM

    2 Pagine

  33. K24 ATEX

    2 Pagine

  34. FHKU LCD

    3 Pagine

  35. PonyFlow5 INOX

    2 Pagine

  36. F3.00

    8 Pagine

  37. M9.02

    4 Pagine

  38. HM...TC-NS

    3 Pagine

  39. HM-TRI

    3 Pagine

  40. HM-F

    8 Pagine

  41. HM/TCR

    4 Pagine

  42. 1800

    1 Pagine

  43. RT

    13 Pagine

  44. HD408T

    2 Pagine

  45. 33/35X

    3 Pagine

  46. RIB300

    3 Pagine

  47. 23/25 ED

    2 Pagine

  48. RIB180

    4 Pagine

  49. FLD48

    2 Pagine

  50. CLS-23

    5 Pagine

  51. PFG05/ATFHV60

    2 Pagine

  52. LFP

    2 Pagine

  53. RIL600

    5 Pagine

  54. LITTLE EX

    1 Pagine

  55. MATIC/V/MC

    2 Pagine

  56. DCX22

    2 Pagine

  57. RIL100

    2 Pagine

  58. VSZ-0O5

    1 Pagine

  59. LEO RECORD

    2 Pagine

  60. EV220B

    13 Pagine

  61. WWG

    1 Pagine

  62. F1

    2 Pagine

  63. CLS

    2 Pagine

  64. K-40

    2 Pagine

  65. KP/KPI

    7 Pagine

  66. miniELCOR

    4 Pagine

  67. EL-USB-4

    5 Pagine

  68. EE33

    6 Pagine

  69. EE300Ex-HT

    6 Pagine

  70. AVFM 5.0

    3 Pagine

  71. EE 75

    5 Pagine

  72. EE776

    6 Pagine

  73. EE771/2

    6 Pagine

  74. TRICOR

    15 Pagine

  75. RIF600W

    4 Pagine

  76. RIF180

    3 Pagine

  77. MC 505

    1 Pagine

  78. HM-R

    3 Pagine

  79. DLM-35

    2 Pagine

  80. DLS-27

    7 Pagine

  81. GRLM70

    9 Pagine