EE31
6Pagine

{{requestButtons}}

Estratti del catalogo

EE31 - 1

TRASMETTITORE UMIDITA' E TEMPERATURA UMIDITA' Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series EE31 offer the ideal solution. The result of many years of experience in humidity measurement technology for industrial applications, the EE31 series builds on the E+E high-quality HC series capacitive humidity sensor elements. Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments The optimal hardware structure for varying applications is achieved by combining various standard mechanical and electronic modules. User friendly MS Windows software tools simplify the configuration of the transmitter, the data recording, visualization and processing. The measured values are available on two freely configurable and scaleable analogue outputs and on the serial RS232 interface. With an optional RS485 module or Ethernet module up to 32 transmitters can be connected to a network and one single PC interface allowing easy remote monitoring. Two freely configurable optional alarm outputs can be set by software. The measured data and the corresponding MIN/MAX values can be viewed on the optional LC display. Other features especially tailored for harsh industrial applications are the new housing concept consisting of three modules, the easy on-site adjustment and calibration, and the pluggable sensor option. These features allow for very fast and easy servicing of the transmitter. By selecting a suitable housing version the EE31 series can be used for the entire range of humidity measurement applications: - Model A for wall mounting - Model B for duct mounting - Model D with remote sensing probe for measurements in the extended temperature range -40...180°C (-40...356°F). - Model E with remote sensing probe for pressure tight applications between 0.01...20 bar (0.15...300psi). Network with up to 32 transmitters Up to 32 transmitters can be connected in a RS-485 bus system to a single PC interface. The measured and calculated data is stored in a PC database which is available for further processing by using the E+E datalogging and analysis software. The data base can also be stored in ASCII format or in a database with ODBC interface. Ethernet interface EE31 transmitters can be connected through a standard Ethernet-port for easy remote monitoring (ordering code E). The software-tools are in the standard scope of supply. 12 v1.5 / Modification rights reserved

Aprire il catalogo a pagina 1
EE31 - 2

Software Tools Configuration Software (included in the scope of supply): The Configuration Software is used for: - flexible, easy and fast setup of the analogue and alarm outputs. - adjustment of the humidity and temperature outputs. - exchange of the sensing probe or of the sensors. Datalogging and Analysis Software (optional): This user friendly software tool is a great help for easy data analysis in graphical or spreadsheet format on a PC as well as for data and alarms management by e-mail or SMS. Easy calibration and adjustment of the transmitter The modular housing of the EE31 enables...

Aprire il catalogo a pagina 2
EE31 - 3

Connection versions plug option C06 power supply+ analogue output power supply+ RS485 network analogue output Dimensions in mm Housing: polycarbonate housing metal housing For use in harsh industrial environments all models of the EE31 are available in a robust metal housing. The very smooth surface and the rounded outlines allow for the use in clean rooms as well. Models: code “cable length” L*) EE31-xAx Wall mounting Probe material: PC code “probe length” EE31-xDx Remote probe for T up to 180°C (356°F) Probe material: stainless steel code “cable length” EE31-xBx Duct mounting Probe...

Aprire il catalogo a pagina 3
EE31 - 4

Technical Data Measurement values Relative humidity 1) Humidity sensor HC1000-400 1) Working *)range 0...100% RH Accuracy (including hysteresis, non-linearity and repeatability, traceable to intern. standards, administrated by NIST, PTB, BEV...) ≤90% RH ± (1.3 + 0.3%*mv) % RH -15...40°C (5...104°F) -15...40°C (5...104°F) >90% RH ± 2.3% RH -25...70°C (-13...158°F) ± (1.4 + 1%*mv) % RH -40...180°C (-40...356°F) ± (1.5 + 1.5%*mv) % RH Temperature dependence of electronics typ. ± 0.01% RH/°C (0.0055% RH/°F) Response time with metal grid filter at 20°C / t90 < 15s Temperature sensor element...

Aprire il catalogo a pagina 4
EE31 - 5

Technical Data for Options Display graphical LC display (128x32 pixels), with integrated push-buttons for selecting parameters and MIN/MAX function Alarm outputs 2 x 1 switch contact 250V AC / 6A 28V DC / 6A can be adjusted with configuration software freely selectable between: RH Relative humidity T Temperature Td Dew-point temperature Tf Frost-point temperature Tw Wet-bulb temperature e Water vapour partial pressure r Mixture ratio dv Absolute humidity h Specific enthalpy Threshold + hysteresis Switching parameters The gray area shows the allowed measurement range for the humidity sensor....

Aprire il catalogo a pagina 5
EE31 - 6

Ordering Guide metal housing polycarbonate housing humidity + temperature Type Model Filter Cable length (incl. probe length) Probe length Pressure tight feedthrough Interface Display Alarm output Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Sensing probe Coating sensor Supply voltage stainless steel sintered filter PTFE filter H2O2 filter stainles steel grid filter (up to 180°C/ 356°F) 2m (6.6ft) 5m (16.4ft) 10m (32.8ft) 20m (65.6ft) 65mm (2.6”) 200mm (7.9”) 400mm (15.8“) 1/2” male thread 1/2” NPT thread RS232 RS485 ethernet interface 1)...

Aprire il catalogo a pagina 6

Tutti i cataloghi e le schede tecniche Riels Instruments

  1. CLF

    2 Pagine

  2. FT1-FT1A

    2 Pagine

  3. D100

    2 Pagine

  4. CLT

    1 Pagine

  5. TS-TSA

    2 Pagine

  6. N2015

    1 Pagine

  7. TQX

    2 Pagine

  8. F3.05

    3 Pagine

  9. PFMV

    6 Pagine

  10. PFMB

    21 Pagine

  11. MS-RI-X

    3 Pagine

  12. RIF600P

    3 Pagine

  13. PF3W

    16 Pagine

  14. FHKSC

    3 Pagine

  15. EPI

    2 Pagine

  16. VZS-005-VA

    1 Pagine

  17. LFE

    22 Pagine

  18. K-PULSER

    2 Pagine

  19. K-EL

    2 Pagine

  20. K-33/44

    2 Pagine

  21. K33 ATEX

    2 Pagine

  22. VZO 4/8

    4 Pagine

  23. VZF

    7 Pagine

  24. VZO 15...50

    7 Pagine

  25. F RANGE

    4 Pagine

  26. KDN

    3 Pagine

  27. KPO

    3 Pagine

  28. ZHM-KL

    5 Pagine

  29. ZHM-ST

    5 Pagine

  30. WI-N

    2 Pagine

  31. AFM/ACM

    2 Pagine

  32. K24 ATEX

    2 Pagine

  33. FHKU LCD

    3 Pagine

  34. PonyFlow5 INOX

    2 Pagine

  35. F3.00

    8 Pagine

  36. M9.02

    4 Pagine

  37. HM...TC-NS

    3 Pagine

  38. HM-TRI

    3 Pagine

  39. HM-F

    8 Pagine

  40. HM/TCR

    4 Pagine

  41. 1800

    1 Pagine

  42. RT

    13 Pagine

  43. HD408T

    2 Pagine

  44. 33/35X

    3 Pagine

  45. RIB300

    3 Pagine

  46. 23/25 ED

    2 Pagine

  47. RIB180

    4 Pagine

  48. FLD48

    2 Pagine

  49. CLM-36

    6 Pagine

  50. CLS-23

    5 Pagine

  51. PFG05/ATFHV60

    2 Pagine

  52. LFP

    2 Pagine

  53. RIL600

    5 Pagine

  54. LITTLE EX

    1 Pagine

  55. MATIC/V/MC

    2 Pagine

  56. DCX22

    2 Pagine

  57. RIL100

    2 Pagine

  58. VSZ-0O5

    1 Pagine

  59. LEO RECORD

    2 Pagine

  60. EV220B

    13 Pagine

  61. WWG

    1 Pagine

  62. F1

    2 Pagine

  63. CLS

    2 Pagine

  64. K-40

    2 Pagine

  65. KP/KPI

    7 Pagine

  66. miniELCOR

    4 Pagine

  67. EL-USB-4

    5 Pagine

  68. EE33

    6 Pagine

  69. EE300Ex-HT

    6 Pagine

  70. AVFM 5.0

    3 Pagine

  71. EE 75

    5 Pagine

  72. EE776

    6 Pagine

  73. EE771/2

    6 Pagine

  74. TRICOR

    15 Pagine

  75. RIF600W

    4 Pagine

  76. RIF180

    3 Pagine

  77. MC 505

    1 Pagine

  78. HM-R

    3 Pagine

  79. DLM-35

    2 Pagine

  80. DLS-27

    7 Pagine

  81. GRLM70

    9 Pagine