Gruppo: Riels Instruments
Estratti del catalogo
FLOW METER Area-Velocity Flow Meter for Open Channels and Pipes No Fiume or Weir Required Model AVFM 5.0 Display,Transmit andTotalize Flow in Open Channels - Measures Reverse Flow -Works in Irregular Channel Shapes Monitor flow through open channels, partially full sewer pipes and sur- charged pipes without a fiume or weir Ideal for municipal stormwater, combined effluent, raw sewage and irrigation water Submersible Ultrasonic Sensor The Riels AVFM 5.0 uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel.The sensor resists fouling, corrosion and abrasion.The flowmeter can be confìgured with the stan- dard submerged velocity-level sensor; or with submerged velocity plus a separate non-contacting ultrasonic level sensor View flowrate and total flow on the large backlit LCD display and connect to external devices with three 4-20mA outputs and two control relays. Measures Velocity + Level with an Ultrasonic Sensor Ultrasonic Flow Monitor for Partially Filled Pipes & Open Channels The AVFM 5.0 Area-Velocity Flow Meter measures both Level andVeloci- tyto calculate flow in an open channel or pipe. Calibration is simple: enter the pipe diameter or channel dimensions and the AVFM 5.0 automatically computes and displays flow volume. The ultrasonic sensor mounts inside the pipe or on the bottom of a chan- nel with a stainless steel mounting bracket (included) and a single screw nto the bottom ofthe pipe or channel. No special compounds, tools or The sensor is completely sealed with no orifìces or ports. Submerged Sensor Measures Level And Velocity Recommended Pipe or Channel Conditions Careful selection of sensor mounting location results in best performance and maintenance-free operation. Avoid locations where sediment builds up. Best possible accuracy will result when the water is not highly turbulent and where velocity is evenly distributed across the channel.The channel should not have drops or direction changes immediately upstream of the sensor mounting location. Pipe or channel slope should not exceed 3%. The AVFM 5.0 can measure forward flow velocity up to 20 ft/sec (6 m/sec) and reverse flow up to 5 ft/sec ( 1.5 m/sec).The electronics and software sample and average flow rates continuously to provide stable readings. The submerged velocity/level sensor will measure flow in partially full and surcharged pipes with pressure up to 10 psi. No special set-up or adjustment s required. Minimum recommended pipe diameter is 6" (I 50 mm). Alternate Sensor Configurations The standard sensor measures both velocity and level with a single submerged probe. It is installed in the pipe or channel floor with the stainless steel mounting bracket (supplied), or mounted with an optional stainless steel band for round pipes. Alternate sensor models are available for special applications: a separate non-contacting ultrasonic level sensor with a submerged velocity sensor Sensor cable can be extended up to Riels Instruments Srl. W+39 049 8961771 - A +39 049 7l7368 .www.riels.it. info@riels.it
Aprire il catalogo a pagina 1Custom Channel Shapes Calibrate the AVFM 5.0 for nstallation in irregular or compound channel shapes by entering the channel width at multiple level points through a simple menu. Channels of virtually any shape can be monitored with your choice of measurement units. Optional 2-Million Point Data Logger Choosethe built-in data logger option ifyou want the AVFM 5.0 to storetime and datestam- ped flow values at 10 second to 60 minute intervals. Daily flow reports are automatically created where total, minimum, maximum and average flow rates are displayed on the LCD display. Transfer log fìles...
Aprire il catalogo a pagina 2New Open Channel Flow Monitor Measures Velocity + Level to calculate Flow AVFM 5.0 Area-Velocity Flow Meter - Measure flow in pipes and open channels of any shape - Ideal where flumes orweirs are diffìcult to instai - Works with water level from I " (25.4 mm) to I 5 ft (4.5 m) - Auto-detects fìeld installation of options including data loggerand control relays Riels AVFM 5.0 Area-Velocity Flow Meter includes a submerged ultrasonic sensorthat is installed atthe bottom of an open pipe or channel. Exposed materials are plastic so the sensor resists fouling and corrosion. It has no moving parts...
Aprire il catalogo a pagina 3Tutti i cataloghi e le schede tecniche Riels Instruments
-
DEEPER Freatimetro
1 Pagine
-
CLF
2 Pagine
-
FT1-FT1A
2 Pagine
-
D100
2 Pagine
-
CLT
1 Pagine
-
TS-TSA
2 Pagine
-
N2015
1 Pagine
-
EE31
6 Pagine
-
TQX
2 Pagine
-
F3.05
3 Pagine
-
PFMV
6 Pagine
-
PFMB
21 Pagine
-
MS-RI-X
3 Pagine
-
RIF600P
3 Pagine
-
PF3W
16 Pagine
-
FHKSC
3 Pagine
-
EPI
2 Pagine
-
VZS-007-VA 97478116
1 Pagine
-
VZS-005-VA
1 Pagine
-
LFE
22 Pagine
-
K-PULSER
2 Pagine
-
K-EL
2 Pagine
-
K-33/44
2 Pagine
-
K33 ATEX
2 Pagine
-
VZO 4/8
4 Pagine
-
VZF
7 Pagine
-
VZO 15...50
7 Pagine
-
F RANGE
4 Pagine
-
KDN
3 Pagine
-
KPO
3 Pagine
-
ZHM-KL
5 Pagine
-
ZHM-ST
5 Pagine
-
WI-N
2 Pagine
-
AFM/ACM
2 Pagine
-
K24 ATEX
2 Pagine
-
FHKU LCD
3 Pagine
-
PonyFlow5 Nylon
1 Pagine
-
PonyFlow5 INOX
2 Pagine
-
F3.00
8 Pagine
-
M9.02
4 Pagine
-
HM...TC-NS
3 Pagine
-
HM-TRI
3 Pagine
-
HM-F
8 Pagine
-
HM/TCR
4 Pagine
-
1800
1 Pagine
-
RT
13 Pagine
-
HD408T
2 Pagine
-
33/35X
3 Pagine
-
RIB300
3 Pagine
-
23/25 ED
2 Pagine
-
RIB180
4 Pagine
-
FLD48
2 Pagine
-
CLM-36
6 Pagine
-
CLS-23
5 Pagine
-
PFG05/ATFHV60
2 Pagine
-
LFP
2 Pagine
-
RIL600
5 Pagine
-
LITTLE EX
1 Pagine
-
MATIC/V/MC
2 Pagine
-
DCX22
2 Pagine
-
RIL100
2 Pagine
-
Flussostato a paletta RIV160
3 Pagine
-
Flussostati a paletta RIV150
2 Pagine
-
VSZ-0O5
1 Pagine
-
Catalogo Riels® Instruments
24 Pagine
-
LEO RECORD
2 Pagine
-
EV220B
13 Pagine
-
WWG
1 Pagine
-
Livellostato laterale RL/L Riels
1 Pagine
-
Valvola_24_riels
4 Pagine
-
Cella_di_carico_off_center_FT6
2 Pagine
-
F1
2 Pagine
-
CLS
2 Pagine
-
Convertitore_OHM_V_1_S102_riels
1 Pagine
-
Indicatore_a_4_cifre_S301_riels
3 Pagine
-
Indicatore_S311A_riels
2 Pagine
-
Data_logger_N2015_riels
1 Pagine
-
MyAlarm2_dispositivo_GSM-GPRS
3 Pagine
-
Datalogger_DCX-22AA_riels
2 Pagine
-
Catalogo_sonde_di_temperatura
62 Pagine
-
Sonde_di_temperatura_MBT_riels
3 Pagine
-
Termostati_KPS_riels
5 Pagine
-
Termostato_RT_riels
13 Pagine
-
Termostato_compatto_MBC_riels
4 Pagine
-
Contalitri_a_turbina_FFU_riels
7 Pagine
-
Contalitri_meccanico_K700M_riels
1 Pagine
-
K-40
2 Pagine
-
Contalitri_a_turbina_FHKSC_riels
3 Pagine
-
Contalitri_a_turbina_FM_riels
2 Pagine
-
Contalitri_a_turbina_FHKU_riels
3 Pagine
-
Sensore_di_portata_F300_riels
8 Pagine
-
Contalitri_a_turbina_F9_riels
12 Pagine
-
Pressostato_digitale_ISE80_riels
7 Pagine
-
KP/KPI
7 Pagine
-
Pressostati_KPS_riels
4 Pagine
-
Pressostati_stagno_RT_riels
13 Pagine
-
Manometro_digitale_LEO1_riels
1 Pagine
-
Manometro_digitale_LEO2_riels
1 Pagine
-
Manometro_digitale_ECO1_riels
1 Pagine
-
miniELCOR
4 Pagine
-
EL-USB-4
5 Pagine
-
EE33
6 Pagine
-
EE300Ex-HT
6 Pagine
-
Temperature Sensors
64 Pagine
-
AVFM 5.0
3 Pagine
-
EE 75
5 Pagine
-
EE776
6 Pagine
-
EE771/2
6 Pagine
-
TRICOR
15 Pagine
-
SE 404 X SE 406 X
2 Pagine
-
RIF600W
4 Pagine
-
RIF180
3 Pagine
-
MC 505
1 Pagine
-
HM-R
3 Pagine
-
DLM-35
2 Pagine
-
DLS-27
7 Pagine
-
GRLM70
9 Pagine
-
FAM_Air_flowmeter_riels
1 Pagine