Gruppo: Riels Instruments
Estratti del catalogo
MASS SENSOR Riels FC300 is a compact Coriolis mass sensor suitable for flow measure- ment of a variety of liquids and gases.The sensor offers superior perfor- mance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a "plug & play" interface ensures optimum A new designed encapsulation in stainless steel with a surprisingly low weight of only 3.5 kg (7.7 Ib), ensures a rigid and robust sensor perfor- mance for a wide range of applications. • High accuracy betterthan 0.1 % of mass flow rate • Large dynamic turn-down ratio betterthan 500:1 • Densitometer performance available through a density accuracy betterthan 0.001 g/cm3 (0.000036 lb/inch3) with a repeatability better • One tube without internai welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications • Larger wall thickness, ensures optimal life-time and corrosion resistance • Balanced pipe design with little mechanical energy loss, ensures optimal performance and stability under non-ideal and unstable process conditions (pressure, temperature, density changes etc). • 4-wire Pt 1000 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow • Multi-plug electrical connectorand SENSORPROM enabletrue "plug & play". Installation and commissioning in less than 10 minutes. • Intrinsically safe Ex design ia IIC as standard • Sensor pipe available in high-quality stainless steel AISI 3 I 6L/I.4435 or Hastelloy C22/2.4602 offering optimum corrosion resistance. • Rugged and space-saving sensor design in stainless steel matching al • High-pressure program as standard • The sensor calibration factor is also valid for gas measurement. The measuring principle is based on the Coriolis effect. The sensor can be connected to ali MASS 6000 transmitters for remote nstallation only. Ali sensors are delivered with a SENSORPROM containing ali information about calibration data, identity and factory pre-programming oftransmit- The industry today has an increasing demand for mass flowmeters with a reduced physical size without loss of performance.The meters must be suitable for installation in traditional process industry environment as well as OEM equipment for instance within automotive or appliance industry. Independent of industry application the meter must deliver accurate and reliable measurements. The new and versatile design ofthe FC300 offers this flexibility. The main applications for the FC300 DN 4 can be found in: Chemical industry Liquid and gas measurement in normal as well as corrosive environments Cosmetic industry_Dosing of essence and fragrances_ Pharmaceutical industry_High-speed dosing and coating of pills, filling of ampuls/injectors r . ... Filling, dosmgof flavormgs, colors and additives, mime density measurement Food and beverage industry ,, 6 . I,. .. „„ _____Measurement and dosing of liquid or gaseous C02_ Automotive industry_Fuel injection nozzle and pump testing, filling of AC units, engineconsumption, paini robots, ABS test-beds The FC300 sensor consiste of a single tube bent in doublé omega pipe geometry welded directly to the process connectors at each end.The sensor is available in 2 material confìgurations, AISI 3 I 6I_/1.4404 or Hastelloy C22/2.4602 with ]4"-NPT or G]4"-ISO process connections. The enclosure is made of stainless steel AISI 31 6L/1.4409 with a grade of encapsulation of IP66/NEMA4.The enclosure has a very robust design and with an overall size of I 30 x 200 x 60 mm (5.12" x 7.87" x 2.36") the sensor is very compact and requires only little installation space. The sensor can be delivered in a standard version with a maximum liquid temperature of I I 5 °C (239 °F) or a high-temperature version, with raised The sensor can be installed in horizontal or vertical position.The sensor can be mounted directly on any given piane surface or if desired with the enclosed quick release clamp fitting which, along with its compact design and multi-plug electrical connector, will keep installation costs and time to a Riels Instruments Srl. ff+39 049 8961771 - A +39 049 7l7368 .www.riels.it. info@riels.it
Aprire il catalogo a pagina 1Installation guidelines for FC300 sensor Horizontal nsrtallation as shown in figure A is recommended with gas or liquid applications.This installatori is also recommended when the flow velocity s low (< I m/s) or the liquid contains solid particles or air bubbles.Vertical installation as shown in figure B can be used for liquid or gas applications. For liquid applications upwards flow is recommended to facilitate the removal of air bubbles and to avoid partly emptying of the sensor For gas applications we recommend to place the flow inlet on the sensor high and the outlet low to remove...
Aprire il catalogo a pagina 2Characteristic curves Pressure drop Riels Instruments Srl. W+39 049 8961771 - A +39 049 7l7368 .www.riels.it. info@riels.it
Aprire il catalogo a pagina 3Tutti i cataloghi e le schede tecniche Riels Instruments
-
DEEPER Freatimetro
1 Pagine
-
CLF
2 Pagine
-
FT1-FT1A
2 Pagine
-
D100
2 Pagine
-
CLT
1 Pagine
-
TS-TSA
2 Pagine
-
N2015
1 Pagine
-
EE31
6 Pagine
-
TQX
2 Pagine
-
F3.05
3 Pagine
-
PFMV
6 Pagine
-
PFMB
21 Pagine
-
MS-RI-X
3 Pagine
-
RIF600P
3 Pagine
-
PF3W
16 Pagine
-
FHKSC
3 Pagine
-
EPI
2 Pagine
-
VZS-007-VA 97478116
1 Pagine
-
VZS-005-VA
1 Pagine
-
LFE
22 Pagine
-
K-PULSER
2 Pagine
-
K-EL
2 Pagine
-
K-33/44
2 Pagine
-
K33 ATEX
2 Pagine
-
VZO 4/8
4 Pagine
-
VZF
7 Pagine
-
VZO 15...50
7 Pagine
-
F RANGE
4 Pagine
-
KDN
3 Pagine
-
KPO
3 Pagine
-
ZHM-KL
5 Pagine
-
ZHM-ST
5 Pagine
-
WI-N
2 Pagine
-
AFM/ACM
2 Pagine
-
K24 ATEX
2 Pagine
-
FHKU LCD
3 Pagine
-
PonyFlow5 Nylon
1 Pagine
-
PonyFlow5 INOX
2 Pagine
-
F3.00
8 Pagine
-
M9.02
4 Pagine
-
HM...TC-NS
3 Pagine
-
HM-TRI
3 Pagine
-
HM-F
8 Pagine
-
HM/TCR
4 Pagine
-
1800
1 Pagine
-
RT
13 Pagine
-
HD408T
2 Pagine
-
33/35X
3 Pagine
-
RIB300
3 Pagine
-
23/25 ED
2 Pagine
-
RIB180
4 Pagine
-
FLD48
2 Pagine
-
CLM-36
6 Pagine
-
CLS-23
5 Pagine
-
PFG05/ATFHV60
2 Pagine
-
LFP
2 Pagine
-
RIL600
5 Pagine
-
LITTLE EX
1 Pagine
-
MATIC/V/MC
2 Pagine
-
DCX22
2 Pagine
-
RIL100
2 Pagine
-
Flussostato a paletta RIV160
3 Pagine
-
Flussostati a paletta RIV150
2 Pagine
-
VSZ-0O5
1 Pagine
-
Catalogo Riels® Instruments
24 Pagine
-
LEO RECORD
2 Pagine
-
EV220B
13 Pagine
-
WWG
1 Pagine
-
Livellostato laterale RL/L Riels
1 Pagine
-
Valvola_24_riels
4 Pagine
-
Cella_di_carico_off_center_FT6
2 Pagine
-
F1
2 Pagine
-
CLS
2 Pagine
-
Convertitore_OHM_V_1_S102_riels
1 Pagine
-
Indicatore_a_4_cifre_S301_riels
3 Pagine
-
Indicatore_S311A_riels
2 Pagine
-
Data_logger_N2015_riels
1 Pagine
-
MyAlarm2_dispositivo_GSM-GPRS
3 Pagine
-
Datalogger_DCX-22AA_riels
2 Pagine
-
Catalogo_sonde_di_temperatura
62 Pagine
-
Sonde_di_temperatura_MBT_riels
3 Pagine
-
Termostati_KPS_riels
5 Pagine
-
Termostato_RT_riels
13 Pagine
-
Termostato_compatto_MBC_riels
4 Pagine
-
Contalitri_a_turbina_FFU_riels
7 Pagine
-
Contalitri_meccanico_K700M_riels
1 Pagine
-
K-40
2 Pagine
-
Contalitri_a_turbina_FHKSC_riels
3 Pagine
-
Contalitri_a_turbina_FM_riels
2 Pagine
-
Contalitri_a_turbina_FHKU_riels
3 Pagine
-
Sensore_di_portata_F300_riels
8 Pagine
-
Contalitri_a_turbina_F9_riels
12 Pagine
-
Pressostato_digitale_ISE80_riels
7 Pagine
-
KP/KPI
7 Pagine
-
Pressostati_KPS_riels
4 Pagine
-
Pressostati_stagno_RT_riels
13 Pagine
-
Manometro_digitale_LEO1_riels
1 Pagine
-
Manometro_digitale_LEO2_riels
1 Pagine
-
Manometro_digitale_ECO1_riels
1 Pagine
-
miniELCOR
4 Pagine
-
EL-USB-4
5 Pagine
-
EE33
6 Pagine
-
EE300Ex-HT
6 Pagine
-
Temperature Sensors
64 Pagine
-
AVFM 5.0
3 Pagine
-
EE 75
5 Pagine
-
EE776
6 Pagine
-
EE771/2
6 Pagine
-
TRICOR
15 Pagine
-
SE 404 X SE 406 X
2 Pagine
-
RIF600W
4 Pagine
-
RIF180
3 Pagine
-
MC 505
1 Pagine
-
HM-R
3 Pagine
-
DLM-35
2 Pagine
-
DLS-27
7 Pagine
-
GRLM70
9 Pagine
-
FAM_Air_flowmeter_riels
1 Pagine