Riels MASS 2100 DI 1.5 is suitable for low flow measurement applications of a variety of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn- down ratio and density accuracy.The ease of nstallation through a "plug & play" mechanical and electrical interface ensures optimum performance The sensor delivers true multi-parameter measurements Le.: Mass flow, volume flow, density, temperature and fraction. • High accuracy betterthan 0.1 % of mass flow rate • Large dynamic turn-down ratio betterthan 500:1, from 65 kg/h to a few g/h • Densitometer performance available through a density accuracy better than 0.001 g/cm3 with a repeatability betterthan 0.0002 g/cm3. • Single continuous tube design, with no internai welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications. • Market's biggest wall thickness, ensuring optimal life-time and corrosion resistance and high-pressure durability • Balanced pipe design with little mechanical energy-loss, ensures optimal performance and stability under non-ideal and unstable process conditions (pressure, temperature, density changes etc). • 4-wire Pt 1000 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow • Multi-plug electrical connectorand SENSORPROM enables true "plug & play". Insrtallation and commissioning in less than 10 minutes • Intrinsically safe EEx ia design as standard • Sensor pipe available in high-quality stainless steel AISI 3 16I_/ 1.4435 or Hastelloy C22/2.4602 offering optimum corrosion resistance • Dual-drive pick-up and driver construction facilitate ultra lowweight pipe construction givingthe markets' smallest and most stable zero • Rugged and space-saving sensor design in stainless steel matching al • High-pressure program as standard • The sensor calibration factor is also valid for gas measurement. The measuring principle is based on the Coriolis effect. The sensor can be connected to ali MASS 6000 transmitters for remote nstallation only Ali sensors are delivered with a SENSORPROM containing ali information about calibration data, identity and factory pre-programming oftransmit- In many industries such as the food and beverage or pharamceutical industry accurate recipe control means everything. The MASS 2100 DI 1.5 has demonstrated superiour performance in numerous applications and fìeld trails relating to accuracy and turn-down ratio. It s today the preferred meterfor research and development and mini-plant applications for liquid or gas measurement, where measuring small quantities The main applications for the MASS 2100 DI 1.5 sensor can be found in: Chemical industry_Liquid and gas measurement within Miniplant and R & D, dosing of additives and catalysts Cosmetic industry_Dosing of essence and fragrances_ Pharmaceutical industry_High-speed dosing and coating of pills, filling of ampuls/injectors_ r . .. ... Dosing of flavourings, colours and additives, density measurement, inline Food and beverage industry _____Measurement of liquid or gaseous CO2_ Automotive industry _ Fuel injection nozzle and pump testing, filling of AC units, engineconsumption, paint robots, ABS test-beds The MASS 2100 sensor consiste of a single bent tube in a doublé omega pipe confìguration, welded directly to the process connectors at each end. The sensor is available in 2 material confìgurations, AISI 3 16I_/ 1.4404 or Hastelloy C22/2.4602 with VA" NPT or VA" ISO process connections. The enclosure is made in stainless steel AISI 31 6L/1.4404 with a grade of encapsulation of IP65/NEMA 4. The sensor is available in either a standard version with a maximum liquid temperature of 125 °C (257 °F) or a high-temperature version, with raised The sensor can be installed in horizontal or vertical position.The enclosed single quick release clamp fìtting which, along with its compact design and single multi-plug electrical connector, wil keep nstallation costs and time to a minimum as shown below. Riels Instruments Srl. TS +39 049 8961771 - A +39 049 7l7368 .www.riels.it. info@riels.it
Aprire il catalogo a pagina 1Installatali guidelines MASS 2100 D11.5 (1/16") Installation of MASS 2100 sensor •The optimal installation is horizontal. If vertical mounting is necessary, upward flow is recommended to facilitate the removal of air bubbles.To remove the air from the sensor the flow speed in the sensor must be at least I m/s. If there are solid particles in the liquid, especially in connection with low flow, it is recommended that the sensor be mounted horizontally with inlet flange uppermost so that particles are more easily flushed out.To ensure that the sensor does not become partially empty there must...
Aprire il catalogo a pagina 2Dimensionai drawings MASS 2100 DI I.S High-temperature version to I80 °C (356 °F) Riels Instruments Srl. W+39 049 896I77I - A +39 049 7l7368 .www.riels.it. info@riels.it
Aprire il catalogo a pagina 3Tutti i cataloghi e le schede tecniche Riels Instruments
-
DEEPER Freatimetro
1 Pagine
-
CLF
2 Pagine
-
FT1-FT1A
2 Pagine
-
D100
2 Pagine
-
CLT
1 Pagine
-
TS-TSA
2 Pagine
-
N2015
1 Pagine
-
EE31
6 Pagine
-
TQX
2 Pagine
-
F3.05
3 Pagine
-
PFMV
6 Pagine
-
PFMB
21 Pagine
-
MS-RI-X
3 Pagine
-
RIF600P
3 Pagine
-
PF3W
16 Pagine
-
FHKSC
3 Pagine
-
EPI
2 Pagine
-
VZS-007-VA 97478116
1 Pagine
-
VZS-005-VA
1 Pagine
-
LFE
22 Pagine
-
K-PULSER
2 Pagine
-
K-EL
2 Pagine
-
K-33/44
2 Pagine
-
K33 ATEX
2 Pagine
-
VZO 4/8
4 Pagine
-
VZF
7 Pagine
-
VZO 15...50
7 Pagine
-
F RANGE
4 Pagine
-
KDN
3 Pagine
-
KPO
3 Pagine
-
ZHM-KL
5 Pagine
-
ZHM-ST
5 Pagine
-
WI-N
2 Pagine
-
AFM/ACM
2 Pagine
-
K24 ATEX
2 Pagine
-
FHKU LCD
3 Pagine
-
PonyFlow5 Nylon
1 Pagine
-
PonyFlow5 INOX
2 Pagine
-
F3.00
8 Pagine
-
M9.02
4 Pagine
-
HM...TC-NS
3 Pagine
-
HM-TRI
3 Pagine
-
HM-F
8 Pagine
-
HM/TCR
4 Pagine
-
1800
1 Pagine
-
RT
13 Pagine
-
HD408T
2 Pagine
-
33/35X
3 Pagine
-
RIB300
3 Pagine
-
23/25 ED
2 Pagine
-
RIB180
4 Pagine
-
FLD48
2 Pagine
-
CLM-36
6 Pagine
-
CLS-23
5 Pagine
-
PFG05/ATFHV60
2 Pagine
-
LFP
2 Pagine
-
RIL600
5 Pagine
-
LITTLE EX
1 Pagine
-
MATIC/V/MC
2 Pagine
-
DCX22
2 Pagine
-
RIL100
2 Pagine
-
Flussostato a paletta RIV160
3 Pagine
-
Flussostati a paletta RIV150
2 Pagine
-
VSZ-0O5
1 Pagine
-
Catalogo Riels® Instruments
24 Pagine
-
LEO RECORD
2 Pagine
-
EV220B
13 Pagine
-
WWG
1 Pagine
-
Livellostato laterale RL/L Riels
1 Pagine
-
Valvola_24_riels
4 Pagine
-
Cella_di_carico_off_center_FT6
2 Pagine
-
F1
2 Pagine
-
CLS
2 Pagine
-
Convertitore_OHM_V_1_S102_riels
1 Pagine
-
Indicatore_a_4_cifre_S301_riels
3 Pagine
-
Indicatore_S311A_riels
2 Pagine
-
Data_logger_N2015_riels
1 Pagine
-
MyAlarm2_dispositivo_GSM-GPRS
3 Pagine
-
Datalogger_DCX-22AA_riels
2 Pagine
-
Catalogo_sonde_di_temperatura
62 Pagine
-
Sonde_di_temperatura_MBT_riels
3 Pagine
-
Termostati_KPS_riels
5 Pagine
-
Termostato_RT_riels
13 Pagine
-
Termostato_compatto_MBC_riels
4 Pagine
-
Contalitri_a_turbina_FFU_riels
7 Pagine
-
Contalitri_meccanico_K700M_riels
1 Pagine
-
K-40
2 Pagine
-
Contalitri_a_turbina_FHKSC_riels
3 Pagine
-
Contalitri_a_turbina_FM_riels
2 Pagine
-
Contalitri_a_turbina_FHKU_riels
3 Pagine
-
Sensore_di_portata_F300_riels
8 Pagine
-
Contalitri_a_turbina_F9_riels
12 Pagine
-
Pressostato_digitale_ISE80_riels
7 Pagine
-
KP/KPI
7 Pagine
-
Pressostati_KPS_riels
4 Pagine
-
Pressostati_stagno_RT_riels
13 Pagine
-
Manometro_digitale_LEO1_riels
1 Pagine
-
Manometro_digitale_LEO2_riels
1 Pagine
-
Manometro_digitale_ECO1_riels
1 Pagine
-
miniELCOR
4 Pagine
-
EL-USB-4
5 Pagine
-
EE33
6 Pagine
-
EE300Ex-HT
6 Pagine
-
Temperature Sensors
64 Pagine
-
AVFM 5.0
3 Pagine
-
EE 75
5 Pagine
-
EE776
6 Pagine
-
EE771/2
6 Pagine
-
TRICOR
15 Pagine
-
SE 404 X SE 406 X
2 Pagine
-
RIF600W
4 Pagine
-
RIF180
3 Pagine
-
MC 505
1 Pagine
-
HM-R
3 Pagine
-
DLM-35
2 Pagine
-
DLS-27
7 Pagine
-
GRLM70
9 Pagine
-
FAM_Air_flowmeter_riels
1 Pagine